 | Introduction |
The primary IDC is truly a state-of-the-art carrier-class (class-A)
facility providing outstanding reliability, availability, and scalability.
It provides fully redundant power, fully redundant carrier connectivity,
and fully redundant upstream IP connectivity, environmental controls,
diverse fire-suppression systems, video surveillance, secure access, and a
carrier-neutral philosophy to deliver superior IDC services backed by one
of the strongest SLA's in hosting industry.
 | Carrier Connectivity |
The primary facility currently houses multiple OC48 (2.45 Gbps) fiber
links to multiple diverse carriers. These OC48 links provide exceptional
scalability, reliability, and redundancy. This core connectivity
infrastructure enables us to maintain and quickly scale multiple
high-speed and redundant fiber links to major Tier 1 Internet backbones,
enabling us to deliver the finest Internet bandwidth quality available.
Multiple, diverse, dual-entranced fiber providers including:
AT&T
SBC
WorldCom
XO Communications
Yipes Enterprise Services
 | Power Generation |
The IDC facilitates a non-stop Internet access infrastructure
utilizing both redundant UPS subsystems and a fully automated and
redundant fail-over to diesel-generator backup power. Dual and fully
redundant 1.2 Megawatt, 480V CAT diesel generators are deployed to provide
non-stop power for mission-critical applications. With 2500 gallons of
onsite fuel storage and contracts for continuous refilling, the non-stop
IDC can run indefinitely due to an N+1 architecture implementation in all
key areas.
 | UPS Subsystem |
Multiple 500KVA EPS6000 MGE UPS subsystems provide fully redundant
power that delivers superior IDC services in a non-stop environment.
 | Fire Suppression |
Fire suppression is one of the very important elements. The IDC
deploys the following systems to provide the most protection from both
fire and the collateral damage caused by conventional fire suppression
systems.
Fire Master (FM-200) gas-based fire suppression
Very Early Smoke Detection Alarm (VESDA) systems
Pre-action, double-interlocked, dry-pipe, suppression
Below floor fire suppression
 | Environmental Controls |
Total environmental control is essential for proper operation and long
life of your equipment. Electronics are susceptible to heat, humidity, and
airborne dust and contaminants. These systems require precision air
conditioning to prevent costly downtime. The IDC is equipped with 175-ton
Liebert HVAC and humidity control systems, raised-flooring for optimum
airflow distribution and management, and constant temperature and humidity
monitoring.
 | Security |
There are various levels of access and monitoring security both inside
and outside of the facility. The first level of security are proximity
card access points to all external building entrances and internal IDC
entrances. Additionally, all cages and secure cabinets are locked with
access only by authorized customers with valid proximity cards or internal
support and service personnel with proximity cards. Private suites employ
biometric palm scanners for secure, authenticated entrance or exit. All
access at each entry or exit is monitored via video recording and
proximity card reader logs. All walls of the IDC are reinforced barrier
design with no windows. A raised-floor IDC design allows all primary
power, Ethernet, Telco, and carrier cables and feeds to be delivered to
their destination completely under the floor and securely out of harms
way.
The entire exterior and interior of the facility is also monitored by
digital video surveillance cameras located throughout the facility
premises. Man-trap (two secure and monitored doors) entrances are also
employed at both the front and rear entrances of the IDC.
|